PDU 2G - Metered - Switched - 0U - Vertical - Black - 24 AC outlet(s) - C13 coupler - C19 coupler

PDU 2G - Metered - Switched - 0U - Vertical - Black - 24 AC outlet(s) - C13 coupler - C19 coupler

AP8858 - Metered - 0U - Vertical - Black - 20 AC outlet(s) - C13 coupler - C19 coupler

Mfg. SKU: AP8858

SKU: 1002628

EAN: 0731304277026

General
PDU types
Metered
Rack capacity
0U
Mounting
Vertical
AC outlets quantity
20 AC outlet(s)
AC outlet types
C13 coupler, C19 coupler
Input connection type
IEC-320 C20
Certification
CSA C22.2 No. 60950,IEC 60950,METI Denan,UL 60950-1,VDE RoHS, REACH
Monitoring
Current, Power, Voltage
Nominal input voltage
230 V
AC input frequency
50 - 60 Hz
Load capacity
3680 VA
$429.45
Availability: On request
Ports & interfaces
AC outlets quantity
20 AC outlet(s)
AC outlet types
C13 coupler, C19 coupler
Input connection type
IEC-320 C20
Output connections
18x IEC 320 C13 2x IEC 320 C19
Design
PDU types
Metered
Rack capacity
0U
Mounting
Vertical
Product colour
Black
Power
Nominal input voltage
230 V
AC input frequency
50 - 60 Hz
Load capacity
3680 VA
Maximum input current per phase
16 A
Maximum total current draw per phase
16 A
Maximum power
3680 W
Operational conditions
Operating temperature (T-T)
5 - 45 °C
Storage temperature (T-T)
-25 - 65 °C
Operating relative humidity (H-H)
5 - 95 %
Storage relative humidity (H-H)
5 - 95 %
Management features
Monitoring
Current, Power, Voltage
Weight & dimensions
Dimensions (WxDxH)
56 x 44 x 902 mm
Weight
2.93 kg
Packaging data
Package dimensions (WxDxH)
162 x 107 x 1124 mm
Package weight
4.2 kg
Features
Certification
CSA C22.2 No. 60950,IEC 60950,METI Denan,UL 60950-1,VDE RoHS, REACH
APC Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers. Users can access and configure Metered Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency.